首页> 外文会议>Symposium on Scientific Basis for Nuclear Waste Management XXV, Nov 26-29, 2001, Boston, Massachusetts, U.S.A. >Effects of Fluoride and Chloride Ions on Corrosion of Titanium Grade 7 in Concentrated Groundwaters
【24h】

Effects of Fluoride and Chloride Ions on Corrosion of Titanium Grade 7 in Concentrated Groundwaters

机译:氟和氯离子对浓缩地下水中钛7级腐蚀的影响

获取原文
获取原文并翻译 | 示例

摘要

Titanium Grade 7 (Ti-7) was tested for both general and local corrosion in environments consisting of fluoride and chloride salts added to simulated groundwaters. Tests were conducted on both U-bends and disks in order to determine the extent of corrosion under stressed and unstressed conditions. The experiments were run over a broad range of temperatures and pH values for periods of up to 164 days. It was found that Ti-7 is susceptible to intergranular attack in some of the test solutions at moderately elevated temperatures, leading to conspicuous localized corrosion. Pitting was detected within 14 days, with pit depths on the order of 0.1 mm. Surface defects appeared to promote the initiation of pitting. The same environment caused stress corrosion cracking failure in a statically stressed U-bend.
机译:在由添加到模拟地下水中的氟化物和氯化物盐组成的环境中,对7级钛(Ti-7)进行了全面腐蚀和局部腐蚀测试。为了确定在压力和非压力条件下的腐蚀程度,对U型弯头和圆盘都进行了测试。实验在宽泛的温度和pH值范围内进行了长达164天的时间。已发现,在某些测试溶液中,Ti-7在中等温度下易受晶间腐蚀,从而导致明显的局部腐蚀。在14天内检测到点蚀,点蚀深度约为0.1毫米。表面缺陷似乎促进了点蚀的产生。相同的环境在静应力U型弯中导致应力腐蚀开裂失败。