首页> 外文会议>Symposium on Fusion Engineering >Electromagnetic and structural analyses of the ITER central solenoid feeders
【24h】

Electromagnetic and structural analyses of the ITER central solenoid feeders

机译:ITER中央螺线管馈线的电磁和结构分析

获取原文

摘要

In the current ITER design, the six central solenoid coils are fed with electrical currents through three upper feeders and three lower feeders. These feeders, that are mounted on the key blocks, are required to withstand cooling and electromagnetic loads through different ITER operation scenarios. The IxB interaction of the currents and the magnetic field exerts loads on the superconducting leads and busbars in the feeders. These loads are transferred to the feeder structures through clamps that hold the conductors along their paths. The upper and lower ITER CS feeder structures including the feeder boxes, bus bars, and coil leads for CS2U and CS2L coils were analyzed using finite element techniques. The coupled Electromagnetic-structural FEM analyses included the effect of electromagnetic forces as well as liquid Helium cooling on the bus bars and coil leads for two different ITER scenarios. The results of these analyses and their implications for the design of feeders are discussed in this paper.
机译:在当前的ITER设计中,六个中央螺线管线圈通过三个上馈线和三个下馈线馈入电流。这些进料器安装在关键块上,需要通过不同的ITER操作方案承受冷却和电磁负荷。电流和磁场的IxB相互作用在馈线中的超导引线和母线上施加了负载。这些负载通过将导体沿其路径固定的夹具转移到馈线结构。使用有限元技术分析了ITER CS的上下馈线结构,包括馈线盒,母线和CS2U和CS2L线圈的线圈引线。耦合的电磁-结构有限元分析包括两种不同ITER情景下电磁力以及液氦冷却对母线和线圈引线的影响。本文讨论了这些分析的结果及其对馈线设计的影响。