The distal radius is a common site of fracture with volar plates and screws as the current clinical practice for fracture fixation [1]. Local measurements of bone quality at the sites of screw insertion aid in providing the most stable fixation with the least amount of hardware, minimizing the risk of construct failure and irritation to soft tissue [2, 3]. The clinical standard for pre-operative bone mineral density (BMD) assessment uses dual x-ray absorptiometry (DEXA). However, DEXA scans provide global BMD values and cannot accurately predict variations in BMD within a given anatomical site [4]. Furthermore, patients frequently present without a pre-operative DEXA scan, so intra-operative assessment would be ideal. We developed a simple sensor system that would be appropriate for assessing local BMD intra-operatively. The system consists of a "smart" Weber clamp instrumented with a single uniaxial strain gage that provides real-time feedback regarding the local BMD.rnThe purpose of this study is to evaluate the in situ performance of the "smart" Weber clamp in predicting local bone strength in the distal radius. Specific aims include 1) to validate the smart Weber clamp for inter and intra-user reliability, 2) to compare Weber clamp bone strength to clinical DEXA measurements in the distal radius, and 3) to compare screw pull-out strength with Weber clamp bone strength.
机译:vol骨远端是is骨板和螺钉骨折的常见部位,是目前骨折固定的临床实践[1]。在螺钉插入部位进行骨质量的局部测量有助于以最少的硬件提供最稳定的固定,从而最大程度地降低构造失败和对软组织刺激的风险[2,3]。术前骨矿物质密度(BMD)评估的临床标准使用双X线骨密度仪(DEXA)。但是,DEXA扫描提供了总体BMD值,无法准确预测给定解剖部位内BMD的变化[4]。此外,患者经常出现而没有术前DEXA扫描,因此术中评估将是理想的。我们开发了一种简单的传感器系统,适用于术中评估局部BMD。该系统由一个装有单个单轴应变计的“智能”韦伯钳组成,该应变仪可提供有关局部BMD的实时反馈。rn本研究的目的是评估“智能”韦伯钳在预测局部BMD方面的现场性能。远端radius骨的骨强度。具体目标包括:1)验证智能Weber夹具在用户之间和用户内部的可靠性; 2)将Weber夹具的骨强度与远端radius骨的临床DEXA测量值进行比较; 3)将螺钉拔出强度与Weber夹具的骨进行比较强度。

著录项

  • 来源
  • 会议地点 Naples FL(US);Naples FL(US)
  • 作者单位

    Biomechanical Testing FacilityrnUCSF/SFGH Orthopaedic Trauma InstituternUniversity of California, San FranciscornSan Francisco, CA USArn Department of Orthopaedic SurgeryrnUniversity of California, San Francisco,rnSan Francisco, CA USA;

    Biomechanical Testing FacilityrnUCSF/SFGH Orthopaedic Trauma InstituternUniversity of California, San FranciscornSan Francisco, CA USArn Department of Orthopaedic SurgeryrnUniversity of California, San Francisco,rnSan Francisco, CA USA;

    Biomechanical Testing FacilityrnUCSF/SFGH Orthopaedic Trauma InstituternUniversity of California, San FranciscornSan Francisco, CA USArn Department of Orthopaedic SurgeryrnUniversity of California, San Francisco,rnSan Francisco, CA USA;

    Biomechanical Testing FacilityrnUCSF/SFGH Orthopaedic Trauma InstituternUniversity of California, San FranciscornSan Francisco, CA USArn Department of Orthopaedic SurgeryrnUniversity of California, San Francisco,rnSan Francisco, CA USA;

    Biomechanical Testing FacilityrnUCSF/SFGH Orthopaedic Trauma InstituternUniversity of California, San FranciscornSan Francisco, CA USArn Department of Orthopaedic SurgeryrnUniversity of California, San Francisco,rnSan Francisco, CA USA;

    et al;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 人体工程学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号