When designing multi-story light-frame structures (i.e. woodrnor metal stud structures) over concrete podiums, lateral loadsrnfrom the structure above the podium will produce largerntensile forces in the overturning restraints. Tensile demandsrnin excess of 100 kips are not unusual. Currently, capacities ofrntension anchors embedded in concrete, when derived fromrnthe American Concrete Institute (ACI) 318-11 Appendix D,rncan be much lower than historic values.rnTests performed as part of an expanding research effort havernfocused on anchorage at both slab edges and center “field”rnlocations. Experimental data shows that the capacity ofrnembedded concrete anchorage can be significantly increasedrnthrough the addition of basic anchorage reinforcement, asrnallowed by ACI 318 Appendix D. This project investigatedrnthe conditions associated with shallow anchoragernreinforcement and its effect on behavior and capacity ofrnembedded anchors subjected to direct tension.rnThis interim report is aimed at providing useful findings torndesign professionals and building code officials forrnfrequently specified anchorage details. Importantrnrecommendations are also made related to constructionrnquality control and overall constructability. The goal of thernfinal test report is to enhance the findings with useful designrnrecommendations and data to support a successful proposal tornchange code provisions.rnThis small, ambitious testing project was initiated by severalrnpracticing engineers in Northern California. The bulk of thernreport findings were made possible by significant technicalrnand financial contributions from industry.
机译:在混凝土裙楼上设计多层轻型框架结构(即木杆金属立柱结构)时,来自裙楼上方结构的横向载荷将在倾覆约束中产生更大的拉力。超过100基普的拉伸需求并不罕见。目前,从美国混凝土协会(ACI)318-11附录D得出的嵌在混凝土中的拉力锚的容量可能远远低于历史值。作为不断扩大的研究工作的一部分,进行的测试集中在平板边缘和中心的锚固。 “现场”位置。实验数据表明,在ACI 318附录D的允许下,通过添加基础锚固加固可以显着提高嵌入式混凝土的锚固能力。该项目研究了与浅锚固相关的条件及其对承受直接拉力的嵌入式锚固的性能和承载力的影响。临时报告旨在为撕裂的设计专业人员和建筑规范官员提供经常发现的锚固细节的有用发现。还提出了有关施工质量控制和整体施工性的重要建议。最终测试报告的目的是通过有用的设计建议和数据来增强调查结果,以支持成功制定变更代码规定的提案。这个小型,雄心勃勃的测试项目是由北加利福尼亚的几名实践工程师发起的。报告的大部分发现是由于工业界的重大技术和财政贡献所致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号