Based on the results of the 10 kW stack, operated for more than 1400 hours in June 1995 the development of components and system was continued. The size of cells was increased to 100 × 100 mm~2 and integrated in one metal bipolar plate using the multiple cell array design. This leads to an electrode area of more than 700 cm~2. Improvement of the cathodes let to current densities of 0.8 A/cm~2 at 0.7 V, using hydrogen with 50 % water and air. As important development goal a 20 kW test facility was designed and constructed. It was set into operation in September 1996, delivering in a first test 7.2 kW with hydrogen/air. Based on this concept, a 100 kW plant is being designed.
机译:根据1995年6月运行了1400多个小时的10 kW烟囱的结果,继续开发组件和系统。电池尺寸增加到100×100 mm〜2,并使用多电池阵列设计集成在一块金属双极板中。这导致电极面积超过700 cm〜2。使用氢气,50%的水和空气,对阴极的改进使电流密度在0.7 V时达到0.8 A / cm〜2。作为重要的发展目标,设计并建造了20 kW的测试设施。它于1996年9月投入运行,首次通过氢气/空气提供7.2 kW的测试功率。基于此概念,正在设计一个100 kW的电站。

著录项

  • 来源
    《Solid oxide fuel cells(SOFC-V)》|1997年|51-60|共10页
  • 会议地点 Aachen(DE);Aachen(DE)
  • 作者单位

    Siemens AG, Power Generation Group Freyeslebenstr. 1, 91058 Erlangen, Germany;

    Siemens AG, Power Generation Group Freyeslebenstr. 1, 91058 Erlangen, Germany;

    Siemens AG, Power Generation Group Freyeslebenstr. 1, 91058 Erlangen, Germany;

    Siemens AG, Power Generation Group Freyeslebenstr. 1, 91058 Erlangen, Germany;

    Siemens AG, Power Generation Group Freyeslebenstr. 1, 91058 Erlangen, Germany;

    Siemens AG, Power Generation Group Freyeslebenstr. 1, 91058 Erlangen, Germany;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 电化学、电解、磁化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号