首页> 外文会议>Solid freeform fabrication proceedings >EXPERIMENTAL DETERMINATION OF OPTIMUM PARAMETERS FOR STAINLESS STEEL 316L ANNEALED ULTRASONIC CONSOLIDATION
【24h】

EXPERIMENTAL DETERMINATION OF OPTIMUM PARAMETERS FOR STAINLESS STEEL 316L ANNEALED ULTRASONIC CONSOLIDATION

机译:实验确定不锈钢316L退火超声波固结的最佳参数

获取原文
获取原文并翻译 | 示例

摘要

Ultrasonic consolidation is being investigated for building Stainless Steel structures. In this study, parameter optimization for ultrasonic consolidation of Stainless Steel 316L annealed is assessed by evaluating experimental factors of oscillation amplitude, welding speed, normal force and temperature. An L-16 Taguchi design was used to establish the statistical significance of these factors and identify the combination of processing parameters that maximizes linear welding density. Optical microscopy was performed to investigate bond quality.
机译:超声波加固正在研究建造不锈钢结构。在这项研究中,通过评估振荡幅度,焊接速度,法向力和温度的实验因素,评估了316L不锈钢退火后的超声波固结的参数优化。 L-16 Taguchi设计用于确定这些因素的统计显着性,并确定使线性焊接密度最大化的工艺参数组合。进行光学显微镜研究粘结质量。

著录项

  • 来源
  • 会议地点 Austin TX(US);Austin TX(US)
  • 作者

    R. Gonzalez; B. Stacker;

  • 作者单位

    Department of Mechanical and Aerospace Engineering, Utah State University, Logan, UT 84322;

    rnDepartment of Mechanical and Aerospace Engineering, Utah State University, Logan, UT 84322;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 产品模型制作 ;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号