This study focused on the measure of the extra oxygen demand for the cometabolic trichloroethylene (TCE) removal by phenol-degrading cells. A respiro meter was used to measure the difference in oxygen consumptions between the phenol removal and both phenol and cometabolic TCE removals. The theoretical equation suggests that the oxygen consumption for phenol biodegradation is 1.65 mg-02/mg-phenol. The oxygen consumptions measured by the respirometer were 1.64 and 1.61 mg-O2/mg-phenol for a duplicate test at an initial phenol concentration of 20 mg/L. The experimental values were very close to the calculated theoretical value (1.65 mg-O_2/mg-phenol). When phenol was used as the substrate to cometabolically remove TCE at initial concentrations of 500 or 1200 μg/L, TCE concentrations decreased to 10 and 403 μg/L after 27 hours of operation, respectively. With the cometabolic TCE removal, the extra oxygen consumptions were 0.2 and 0.4 mg for initial TCE concentrations at 500 and 1200 mg/L, respectively. According to the extra oxygen demand and the TCE removal, the oxygen demands for the cometabolic TCE removal were 0.41 and 0.51 mg-O_2/mg-TCE at initial TCE concentrations of 500 and 1200 μg/L, respectively. The experimental result (average 0.46) was close to the theoretical value (0.37 mg-O_2/mg-TCE) calculated from a postulated equation.
机译:这项研究的重点是通过苯酚降解细胞去除可代谢三氯乙烯(TCE)所需的额外氧气。使用呼吸计测量苯酚去除与苯酚和新陈代谢TCE去除之间的耗氧量差异。理论方程表明,苯酚生物降解的耗氧量为1.65 mg-02 / mg-苯酚。对于重复测试,在初始苯酚浓度为20 mg / L时,通过呼吸计测得的氧气消耗量为1.64和1.61 mg-O2​​ / mg-苯酚。实验值非常接近于计算的理论值(1.65 mg-O_2 / mg-苯酚)。当使用苯酚作为底物以500或1200μg/ L的初始浓度进行代谢代谢去除TCE时,操作27小时后,TCE浓度分别降至10和403μg/ L。去除代谢性三氯乙烯后,初始三氯乙烯浓度分别为500和1200 mg / L时,额外的氧气消耗分别为0.2和0.4毫克。根据额外的需氧量和三氯乙烯的去除,在初始三氯乙烯浓度为500和1200μg/ L时,去除代谢性三氯乙烯的氧气需求分别为0.41和0.51 mg-O_2 / mg-TCE。实验结果(平均值为0.46)接近从假定方程式计算出的理论值(0.37 mg-O_2 / mg-TCE)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号