On-line monitoring techniques for leakage current of contaminated insulators are introduced. Because the leakage current is weak and wide-banded, in order to measure it accurately in strong electromagnetic interference, a series of effective methods are adopted and realized, such as designing a special signal-acquisition instrument, realizing synchronal measurement, ect. The attributes of interference sources are analyzed. The key techniques both in software and hardware to suppress all kinds of interference and eliminate various noises are also presented.
机译:介绍了污染绝缘子泄漏电流的在线监测技术。由于泄漏电流较弱且带宽较宽,为了在强电磁干扰下准确测量泄漏电流,采用并实现了一系列有效的方法,例如设计专用的信号采集仪,实现同步测量等。分析了干扰源的属性。还介绍了软硬件中抑制各种干扰并消除各种噪声的关键技术。