摘要

After three attempts in the last 6 years to fully characterize the reservoir in the Caballos Formation in the Puerto Colon Field, different approaches to explain the reservoir heterogeneity have been suggested, each of which involves a great deal of uncertainty. Of particular importance is the fact that the oil-water contact has been found at varying depths from well to well. This variation could not be satisfactorily explained structurally nor stratigraphically. Bouttete et al, 1993, on the basis of incomplete 2D seismic information integrated to an extensive set of geologic and engineering data stated that there are three different reservoirs in the Caballos Formation. In 1996, Calderon et al, using additional well and seismic data, concluded that there is a single tilted oil water contact in the Formation. There is strong evidence supporting each of these models but there are still some inconsistencies. Recently, Pena et al, performed a thorough structural, stratigraphic and petrophysical review. This latest approach considered improved data management procedures and geostatistical modelling in order to produce a better picture of the reservoir. A rigorous validation and integration process under a project database allowed the workteam to improve the understanding of the system under study. By combining geostatistical modeling with geologic expertise it was possible to reduce much of the uncertainty and choose the most probable static and dynamic models of the reservoir. It was found that there are not sufficient elements in the static and dynamic models to account for the existence of three different reservoirs. A tilted OWC was accepted as the best representation of the reservoir for the available information.
机译:在过去6年中进行了3次尝试以全面描述波多黎各科隆油田卡瓦洛斯组的储层特征之后,提出了不同的解释储层非均质性的方法,每种方法都存在很大的不确定性。尤为重要的事实是,发现油水接触的深度在不同的井之间。在结构上或地层上都不能令人满意地解释这种变化。 Bouttete等人,1993年,在将不完整的2D地震信息整合到大量地质和工程数据的基础上,指出Caballos组中存在三个不同的储层。 1996年,Calderon等人使用额外的油井和地震数据得出的结论是,地层中只有一个倾斜的油水接触。有确凿的证据支持每种模型,但仍然存在一些不一致之处。最近,Pena等人进行了全面的结构,地层和岩石物理研究。该最新方法考虑了改进的数据管理程序和地统计学模型,以便对储层进行更好的描述。在项目数据库下的严格验证和集成过程使工作团队可以提高对所研究系统的理解。通过将地统计学模型与地质专业知识相结合,可以减少很多不确定性,并选择最可能的储层静态和动态模型。发现静态和动态模型中没有足够的元素来说明三个不同储层的存在。对于可用信息,倾斜的OWC被认为是储层的最佳表示。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号