Method for determining selective capability of current-limiting overcurrent devices using peak-let-through current “What traditional time current curves will not tell you”

机译:使用峰值穿通电流确定限流过电流设备选择性能力的方法“传统时间电流曲线不会告诉您什么”

获取原文

摘要

Time-Current-Curves are accepted industry standard for predicting overcurrent device operation and analyzing selective behavior under overload, or fault conditions. A conservative interpretation of curves has sufficed for many years and provided acceptable performance. However, recent emphasis on better selectivity while trying to provide optimal protection demands more accurate selectivity predictions. Currently, manufacturers are publishing tables and other guidelines to facilitate the selection of optimally coordinated devices. However, no standard or single method exists for the creation of these tables. The writers shall present three methods of device interaction analysis based on peak let-through current, suitable for predicting selective behavior of protective devices above what time current curves may indicate. The methods may be applied with published information or manufacturer's internal test information.
机译:时间-电流曲线是公认的行业标准,用于预测过电流设备的运行情况并分析过载或故障条件下的选择性行为。对曲线的保守解释已经足够了很多年并且提供了可接受的性能。但是,最近在试图提供最佳保护的同时强调更好的选择性要求更准确的选择性预测。当前,制造商正在发布表格和其他指南,以帮助选择最佳协调的设备。但是,不存在用于创建这些表的标准或单一方法。作者将介绍三种基于峰值通过电流的设备相互作用分析方法,适用于在电流曲线可能指示的时间以上预测保护设备的选择性行为。该方法可以与已发布的信息或制造商的内部测试信息一起使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号