首页> 外文会议>Progress in Environmental Science and Technology >Discussion of the Main Influencing Factors during Electro-Fenton Process
【24h】

Discussion of the Main Influencing Factors during Electro-Fenton Process

机译:电芬顿过程中主要影响因素的探讨

获取原文

摘要

A three electrode system was set up for the electro-Fenton process, in which graphite, Pt and saturated calomel electrode were used as cathode, anode and reference electrode respectively, and Na2SO4 as supporting electrolyte. The main influencing factors of the electro-Fenton process, including pH of cathode electrolyte, current density, oxygen flow, concentration of supporting electrolyte and electrode distance, were examined and discussed in this work. According to the orthogonal test, the optimal parameter combination was: pH=2.0, current density=10.2 A/m2, oxygen flow=0.4 L/min, concentration of supporting electrolyte=0.1 mol/L, electrode distance=6cm. Moreover, the feasibility of exploring new kind of or compound catalyst to overcome the demanding acid condition was investigated, and the ways, including using air as oxygen supply and improve the utilization ratio of electric energy, were also discussed in this paper.
机译:建立了用于电子芬顿法的三电极系统,其中石墨,铂和饱和甘汞电极分别用作阴极,阳极和参比电极,而硫酸钠则用作支持电解质。本文研究并讨论了电芬顿过程的主要影响因素,包括阴极电解质的pH值,电流密度,氧气流量,支持电解质的浓度和电极距离。根据正交试验,最佳参数组合为:pH = 2.0,电流密度= 10.2A / m2,氧气流量= 0.4L / min,支持电解质浓度= 0.1mol / L,电极距离= 6cm。此外,研究了探索新型的或复合的催化剂以克服苛刻的酸性条件的可行性,并探讨了使用空气作为氧气供应和提高电能利用率的方法。