Thermal environment and air flow condition in small assembly room at typical summer weather was studied by numerical simulation and experiment. Numerical simulation was based on the indoor zero-equation turbulence model using momentum method and N-point model as boundary condition of air supply opening respectively. It was found that the N-point model at N=3 as inlet boundary condition to simulate louver supply opening with certain angles gives a good simulation result. A method of simulating heat-gain by solar radiation was proposed. It gives considerable comparable temperature gradient above 0.2m height. Ultimately, the thermal comfort evaluation was given as separated air-conditioning unit supply low temperature air to the room.
机译:通过数值模拟和实验研究了典型夏季夏季小型装配室的热环境和空气流动状况。在室内零方程湍流模型的基础上,采用动量法和N点模型作为送风口的边界条件进行了数值模拟。结果发现,以N = 3的N点模型作为进口边界条件,模拟一定角度的百叶窗进风口,具有良好的仿真效果。提出了一种模拟太阳辐射热增益的方法。它在0.2m高度以上给出相当可比的温度梯度。最终,对热舒适性进行了评估,因为分开的空调单元向房间供应了低温空气。