首页> 外文会议>Proceedings of the Solar 99 conference : Including proceedings of ASES annual conference, proceedings of 24th national passive solar conference >Setting the baseline for the building envelope: the update to standard 90.1-the national energy standard for buildings
【24h】

Setting the baseline for the building envelope: the update to standard 90.1-the national energy standard for buildings

机译:设置建筑物围护结构的基准线:更新为标准90.1(国家建筑物的能源标准)

获取原文
获取原文并翻译 | 示例

摘要

Energy Codes provide a baseline for energy efficiency in construction. They are frequently used for comparison purposes when designers wish to express the degree of energy efficiency in their design. ASHRAE/IESNA Standard 90.1 is cited in the 1992 U. S. National Energy Policy Act as the baseline for State Commercial Energy Codes. This paper summarizes the draft update to the building envelope requirements including the consideration of daylighting, U-factor, solar heat gain coefficient, visible light transmittance, overhangs, thermal mass, insulation location, roof reflectance and other factors in setting the criteria for the prescriptive and tradeoff compliance options for opaque components and fenestration (including windows, doors, and skylights).
机译:能源法规为建筑节能提供了基准。当设计师希望表达其设计中的能效程度时,通常将它们用于比较目的。 1992年《美国国家能源政策法》引用了ASHRAE / IESNA标准90.1作为州商业能源法规的基准。本文总结了建筑围护结构要求的更新草案,其中包括在设置说明标准时要考虑的因素包括采光,U因子,太阳热增益系数,可见光透射率,悬挑,热质量,隔热位置,屋顶反射率和其他因素。以及不透明组件和开窗(包括窗户,门和天窗)的权衡合规性选项。