首页> 外文会议>Proceedings of building simulation 2003: proceedings of eighth IBPSA conference and exhibition >NUMERICAL SIMULATION ON THE PREVENTION EFFECT OF THE COLDDRAFT ALONG THE WINDOW IN WINTERTIME
【24h】

NUMERICAL SIMULATION ON THE PREVENTION EFFECT OF THE COLDDRAFT ALONG THE WINDOW IN WINTERTIME

机译:冬季沿窗漏水预防效果的数值模拟

获取原文
获取原文并翻译 | 示例

摘要

This study is aimed to contribute to energy saving andrnto achieve the indoor thermal comfort by preventingrnthe down draft along the window in building with lessrnheating energy than the common equipment, e.g. FCU.rnFirstly for the counter along the perimeter equippedrnwith the heat panel, the flow inlet, the flow outlet andrnthe declined plate over the counter, the 2-Drnsimulations of 64 cases with varying the configurationrnof the counter, the heat generation rate, etc. arernexecuted. As the result, the heat panel with 25% lessrnheat generation rate than the heat flux through thernwindow can prevent the cold draft under the conditionrnof the inlet width 8cm, the outlet width 8cm and therncounter plate declined with the angle of 30 degree orrnmore. Furthermore the executed simulation under 14rnconditions suggests the advantage of short-circuitrnphenomenon.
机译:这项研究旨在通过以比普通设备少的热能来防止建筑物中沿窗户的向下通风,从而为节能和实现室内热舒适性做出贡献。 FCU。首先对沿装有加热板,进水口,出水口和柜台上的下降板的周边的柜台执行64种情况下的2-D模拟,改变柜台的配置,产热率等。 。结果,在入口宽度为8cm,出口宽度为8cm且柜台板以30度或更大的角度下降的条件下,热量产生率比通过窗户的热通量少25%的热板可以防止冷风。此外,在14个条件下执行的仿真表明了短路现象的优势。