Electrical contact manufacturers have the continuous challenge to reduce cost and improve performances with better material. Many historical practices in the selection of contacts in regard to contact erosion, welding and contact resistance have to be revisited to find updated guidelines. In this report, some contact combinations for low voltage circuit breaker applications using Ag/W as moving contact against Ag/MeO as stationary contact are evaluated on welding, endurance and contact resistance. This included metal oxides such as CdO, SnO2 and ZnO. The results are compared with the more conventional mating of Ag/W to Ag/C and Ag/WC/C which have low contact resistance but high erosion and low strength deficiencies. In these asymmetrical contact combinations, contact welding and endurance tests at 90A are compared with some composition variations. Arc erosion products and material transfer affecting changes in contact resistance are examined in composition analysis and metallography. Contact resistance vs contact force is measured to show the possible improvements to heat rise factors.
机译:电触头制造商一直面临着不断降低成本,提高材料性能的挑战。关于接触腐蚀,焊接和接触电阻的接触选择方面的许多历史惯例必须重新审视,以找到更新的指南。在此报告中,针对使用Ag / W作为Ag / MeO作为固定触点的动触头的低压断路器应用,对某些触头组合进行了焊接,耐久性和接触电阻的评估。其中包括金属氧化物,例如CdO,SnO2和ZnO。将结果与较传统的Ag / W与Ag / C和Ag / WC / C的配合相比较,后者具有较低的接触电阻,但腐蚀率高且强度不足。在这些不对称的触点组合中,将90A时的触点焊接和耐久性测试与某些成分变化进行了比较。在成分分析和金相学中检查了影响接触电阻变化的电弧腐蚀产物和材料转移。测量了接触电阻与接触力的关系,以显示出热量上升因子的可能改善。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号