IEC 61850-7-420 data object modeling for Smart control islanding detection

机译:IEC 61850-7-420数据对象建模,用于智能控制孤岛检测

获取原文
获取原文并翻译 | 示例

摘要

Energy systems are gaining more evolution upon the incoming boom of the distributed energy resources (DERs). In order to sustain an efficient electrical energy systems operation and reduce hazard for the Electrical Utilities personals within such dynamic and adaptable systems structure behavior that handle numerous parameters and variables. A new islanding detection technique is proposed. The proposed approach relies on the electrical grid communication system network upon the IEC 61850-7-420 standard. Electrical grid distributed main management service (DMMS) takes the response to monitor all the electrical connection points (ECP) and the DERs status. Measurements for the electrical grids operation parameters (e.g. frequency, active and reactive power, etc.) are not needed. In addition, successful implementation for the proposed solution upon a design modeling and simulation works for prototype of a micro grid that utilized extensive communication based on IEC 61850 to monitor all the micro grid data objects. The monitoring task facilitates the updating of the micro grid structure and the indiscriminating between the normal electrical grid transient events (DERs out from the grid, instantaneous loads changes, faults etc.) and the actual islanding scenarios that increase the reliability and availability of the electric grids.
机译:随着分布式能源(DER)的到来,能源系统正在获得更多发展。为了维持有效的电能系统运行并减少这种动态和适应性系统结构中对电力公用事业人员的危害,该行为处理许多参数和变量。提出了一种新的孤岛检测技术。所提出的方法依赖于基于IEC 61850-7-420标准的电网通信系统网络。电网分布式主管理服务(DMMS)采取响应以监视所有电气连接点(ECP)和DER状态。不需要测量电网运行参数(例如频率,有功和无功功率等)。此外,针对提议的解决方案的成功实现基于微网格原型的设计建模和仿真工作,该微网格利用基于IEC 61850的广泛通信来监视所有微网格数据对象。监视任务有助于微电网结构的更新以及正常电网瞬态事件(电网中的DER脱离,瞬时负载变化,故障等)与实际孤岛方案之间的不加区分,从而提高了电力的可靠性和可用性网格。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号