Transformer is one of the very important components of Electrical power system. Transformers are invariably protected by using differential protection. But the differential protection sometime may malfunction due to inrush current whenever a transformer is energized. Several methods like per-phase method, cross blocking method, Percent average blocking method and Harmonic sharing method are already in existence. This paper provides an even more sophisticated and reliable method of distinguishing between fault current and magnetizing inrush by employing fuzzy logic.
机译:变压器是电力系统的重要组成部分之一。通过使用差动保护始终可以保护变压器。但是,每当变压器通电时,由于涌入电流,有时差动保护可能会发生故障。每相方法,交叉阻塞方法,百分比平均阻塞方法和谐波共享方法已经存在。本文提供了一种使用模糊逻辑来区分故障电流和励磁涌流的更加复杂,可靠的方法。