Electrical measurement is widely applied as a test method that analyzes the strain of components in engineering and features in small size, light weight, simple operation and high measure precision. Before they are put into production, roof anchors in the Three Gorges underground plant, as an important means of hoisting by overhead traveling cranes, were load-tested for security during which the strain of the roof anchor shanks was measured over the load bearing and changes thereof on the roof anchor shanks. The measurement result proves that the measured values by the resistance strain gauges shows evident regularity and all measured resistances are within the designed permissible range, suggesting that the roof anchors are safe.
机译:电气测量被广泛用作一种测试方法,该方法可以分析工程中的零件应变,并且具有体积小,重量轻,操作简单和测量精度高的特点。在投入生产之前,对三峡地下工厂的屋顶锚(作为高架起重机吊装的重要手段)进行了安全性负载测试,在此过程中,测量了在承载和变化情况下屋顶锚杆的应变。其在屋顶锚杆上。测量结果表明,电阻应变计的测量值显示出明显的规律性,并且所有测得的电阻均在设计的允许范围内,表明屋顶锚是安全的。