首页> 外文会议>Proceedings of the 13th International Power Electronics Congress >A reduced-order generalized average model for a grid-connected HF-link micro-inverter
【24h】

A reduced-order generalized average model for a grid-connected HF-link micro-inverter

机译:并网HF-link微逆变器的降阶广义平均模型

获取原文
获取原文并翻译 | 示例

摘要

This paper presents a reduced-order generalized average model for a grid-connected High-Frequency-link micro-inverter for renewable energy sources applications; the grid-connected topology is based on the DC/DC Dual-Active-Bridge (DAB) converter without the intermediate DC-link. The switched model for the system is presented and from it the reduced-order generalized average model is obtained. Harmonic spectra are presented from the simulation results for the specialized software PSIM and compared with the switched and reduced-order generalized average models computed in MATLAB-Simulink for the open-loop system, the simulation results are validated through experimental results.
机译:本文提出了可再生能源应用的并网高频链路微型逆变器的降阶广义平均模型。并网拓扑是基于DC / DC双主动桥(DAB)转换器而没有中间DC链路的。给出了系统的切换模型,并从中获得了降阶广义平均模型。从专用软件PSIM的仿真结果中给出了谐波谱,并与在MATLAB-Simulink中为开环系统计算的开关和降阶广义平均模型进行了比较,仿真结果通过实验结果得到了验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号