【24h】

FINAL RESULTS OF SHIPBOARD HYDROTHERMAL OXIDATION WITH A TRANSPIRING WALL REACTOR

机译:带有蒸发壁反应器的船板水热氧化的最终结果

获取原文
获取原文并翻译 | 示例

摘要

A hydrothermal oxidation (HTO) plant utilizing a transpiring wall reactor design for processing shipboardrnorganic wastes has been tested. The plant is designed to destroy common naval vessel excess hazardous materialsrn(EHM) at a nominal waste feed rate of 45 kg/hr. Corrosive wastes including a chlorinated solvent, chlorinated/fluorinatedrnsynthetic oil and a salt producing photographic solution simulant have been processed at feed ratesrnbetween 45-95 kg/hr. Tests have been conducted at a nominal operating pressure of 24.1 MPa with internal reactorrntemperatures between 594 and 816℃. The process oxidant is compressed air. Total organic carbon destructionrnremoval efficiencies of better than 99.99% have been obtained for all validation tests. Measurements of NOX andrnCO concentrations are normally below 25 ppm and 100 ppm, respectively. Liquid effluent total organic carbonrn(TOC) levels are consistently below 3.5 ppm. Post-test inspections have not revealed any obvious reactor liner corrosionrnor salt deposition concerns.
机译:已经测试了采用透热壁反应器设计的热氧化工厂,该工艺用于处理船用有机废物。该工厂旨在以45 kg / hr的名义废物进料速度销毁普通海军舰船上的过量有害物质(EHM)。含氯溶剂,氯化/氟化合成油和制盐照相溶液模拟物等腐蚀性废物的进料速度为45-95 kg / hr。在标称工作压力为24.1 MPa且内部反应堆温度为594至816℃的条件下进行了测试。过程氧化剂是压缩空气。所有验证测试的总有机碳销毁去除效率均高于99.99%。 NOX和rnCO浓度的测量值通常通常分别低于25 ppm和100 ppm。液体废水的总有机碳(TOC)水平始终低于3.5 ppm。测试后检查未发现任何明显的反应堆衬管腐蚀或盐沉积问题。