首页> 外文会议>Precision Electromagnetic Measurements (CPEM), 2012 Conference on >PTB - UNIIM bilateral comparison on current transformer measurement systems at currents up to 60 000A
【24h】

PTB - UNIIM bilateral comparison on current transformer measurement systems at currents up to 60 000A

机译:PTB-UNIIM对电流高达60 000A的电流互感器测量系统进行的双边比较

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

This paper presents the results of a bilateral comparison of current transformer measurement systems at 50 Hz between PTB (pilot laboratory) and UNIIM. The comparison is registered at COOMET with the identifier 513/DE-a/10. The comparison of the systems using two two-stage current transformers from UNIIM and the data processing have been finished. The results agree within 6 µA / A for the current ratio errors and 8 µrad for the phase displacements at all current ratios from 1 A / 1 A to 50 kA / 5 A and at all test points from 1 % to 120 %. The associated EN factors are below 0.6.
机译:本文介绍了PTB(试点实验室)和UNIIM在50 Hz时互感器测量系统的双边比较结果。该比较以标识符513 / DE-a / 10在COOMET注册。使用两个来自UNIIM的两级电流互感器的系统比较和数据处理已经完成。在1 A / 1 A至50 kA / 5 A的所有电流比以及1%至120%的所有测试点上,电流比误差的结果在6 µA / A内,相位移在8 µrad内。相关的EN因子低于0.6。