This project enabled a large gas-fired unit (consisting of one conventional once-throughrnboiler and one steam turbine repowered with two gas turbines and relevant heat recoveryrnsteam generators ) normally operating at an efficiency, at unit full load (900 MW), of aboutrn43% (therefore higher than traditional thermal power stationsrnbut lower than new generationrncombined cycles), to be competitive on the electric power market of the future selling anrneconomically valuable power reserve while operating at around 320 MW, with an efficiencyrnclose to nominal even with this minimum load.rnThe 320 MW total load is obtained operating the unit (one steam turbine and two gas turbines)rnin pure combined cycle mode (I.e. with the main boiler out of operation ).rnThe pure combined cycle operation mode of this type of power plant, as designed by Ansaldornin co-operation with Enel Produzione, represents an absolute innovation on the internationalrnmarket.
机译:该项目使一台大型燃气机组(由一台常规的直流锅炉和一台由两台燃气轮机和相关的热回收蒸汽发生器重新供电的蒸汽轮机组成)正常运行时,单位满负荷(900兆瓦)的效率约为43%。 (因此比传统的火力发电厂要高,但比新一代的联合循环要低),要在未来的电力市场上具有竞争力,并在320兆瓦左右的功率下运行,具有经济价值的动力储备,即使在最小负载下,效率也接近标称值。在纯联合循环模式下(即主锅炉不运行),运行单元(一个蒸汽轮机和两个燃气轮机)的总负荷为320 MW。 Ansaldornin与Enel Produzione的合作代表了国际市场上的绝对创新。

著录项

  • 来源
    《POWER-GEN Europe 2004 》|2004年|1-14|共14页
  • 会议地点 Barcelona(ES)
  • 作者

  • 作者单位
  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号