Widespread application of power electronics in industrial and residential loads has increased the harmonics of the grid significantly. The grid harmonics have destructive impacts on the gird components including distribution transformers. Studying the impacts of current harmonics on distribution transformers is crucial for grid design and maintenance. Therefore, this paper studies the effect of gird harmonics on eddy current loss, other stray losses, hottest spot temperature, and lifetime of distribution transformers. The current harmonics of six 100KVA transformers at a provincial power distribution center are measured in a one week test period and the impacts of grid harmonics on the investigated transformer are thoroughly discussed.
机译:电力电子在工业和住宅负载中的广泛应用已大大增加了电网的谐波。电网谐波对包括配电变压器在内的电网部件具有破坏性影响。研究电流谐波对配电变压器的影响对于电网设计和维护至关重要。因此,本文研究了电网谐波对涡流损耗,其他杂散损耗,最热点温度和配电变压器寿命的影响。在一个为期一周的测试期内,对某省级配电中心的六台100KVA变压器的电流谐波进行了测量,并彻底讨论了电网谐波对所研究的变压器的影响。