EFFECT OF SURFACE-STRAIN SAMPLING INTERVAL ON THE RELIABILITY OF PRETENSIONED CONCRETE RAILROAD TIE TRANSFER LENGTH MEASUREMENTS

机译:表面应变取样间隔对预应力混凝土铁路平移传递长度测量结果可靠性的影响

获取原文
获取原文并翻译 | 示例

摘要

The feasibility of fully-automated in-plant transfer length measurement for prestressed concrete railroad cross-ties has been suggested from recent progress in the development of robust optical surface strain measurement. The non-contact Laser Speckle Imaging (LSI) technique provides rapid and accurate surface strain profile data—a key requirement if continuous monitoring of cross-tie transfer length is to be achieved in a production plant setting as a quality control parameter. Using an automated LSI system, strain data was taken at an unprecedented resolution of 0.5 inch increments during recent extensive in-plant crosstie testing. This provided a large data base for investigation of the minimum sampling interval required for accurate transfer length measurement. Using high-resolution in-plant strain data from a sampling of crossties,, the effect of sampling interval on transfer length assessment is evaluated and compared with previous theoretical analysis of transfer length measurement uncertainty. Statistical analysis of this real in-plant crosstie data shows that the influence of sampling interval on crosstie transfer length uncertainty agrees well with analysis developed earlier for constant cross-section prismatic members. Furthermore, these results indicate that it may be possible to rapidly and accurately assess transfer length with only a few discrete measurements of surface strain along the crosstie.
机译:从坚固的光学表面应变测量的最新进展中,已经提出了用于预应力混凝土铁路枕木的全自动工厂内传递长度测量的可行性。非接触式激光散斑成像(LSI)技术可提供快速而准确的表面应变曲线数据,这是在生产工厂中要连续监视交叉结转移长度作为质量控制参数的一项关键要求。使用自动LSI系统,在最近的广泛厂内交叉结测试期间,以0.5英寸增量的前所未有的分辨率获取了应变数据。这为调查准确的传输长度测量所需的最小采样间隔提供了广阔的数据库。使用来自交叉点采样的高分辨率厂内应变数据,评估采样间隔对传输长度评估的影响,并将其与传输长度测量不确定度的先前理论分析进行比较。对实际工厂内交叉结数据的统计分析表明,采样间隔对交叉结转移长度不确定性的影响与之前针对恒定横截面棱柱形构件开发的分析非常吻合。此外,这些结果表明,仅通过沿交叉点的表面应变的少量离散测量即可快速而准确地评估转移长度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号