【24h】

Nonequilibrium plasma MHD power generation with FUJI-1 blow-down facility

机译:具有FUJI-1排污设施的非平衡等离子体MHD发电

获取原文
获取原文并翻译 | 示例

摘要

Experimental studies on closed cycle MHD power generation with "Fujil" blow-down facility at Tokyo Institute of Technology are presented. Recently, a new disk generator (Disk-F4) has been installed and a new seed injection system has been introduced from IVTAN (Institute of High Temperature in Russia). The design concept of the new generator channel is focused mainly on the reliability of high power generation. In the new seeding system, a melted seed material is pushed by a piston dozator, instead of gas-pressure-driven in the previous system. In the power generation experiments with the new components, the maximum power output of 502kW and the enthalpy extraction ratio of 16.7
机译:本文介绍了东京工业大学使用“ Fujil”排污设施进行闭环MHD发电的实验研究。最近,已经安装了新的磁盘发生器(Disk-F4),并从IVTAN(俄罗斯高温研究所)引入了新的种子注入系统。新发电机通道的设计概念主要集中在高发电的可靠性上。在新的播种系统中,熔化的种子材料由活塞推料器推动,而不是在以前的系统中由气压驱动。在使用新组件进行的发电实验中,最大功率输出为502kW,焓提取比为16.7