首页> 外文会议>Optics for High-Brightness Synchrotron Radiation Beamlines >Optical design and fabrication of the off-axis paraboloid and ellipsoidal mirrors of beamline for synchrotron radiation biological spectroscopic experiments
【24h】

Optical design and fabrication of the off-axis paraboloid and ellipsoidal mirrors of beamline for synchrotron radiation biological spectroscopic experiments

机译:同步辐射生物光谱实验的光束线离轴抛物面和椭球面镜的光学设计和制造

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Abstract: At present beamline 3B1 in Synchrotron Radiation Lab. of Beijing Electron Position Collider has been set up for soft X-ray photolithography experiment. 3B1B beamline branched from beamline 3B1 operates at VUV-VIS for biological spectroscopic experiment. This paper describes design and fabrication on optical system of 3B1B. The features of optical system design is to adopt an off-axis paraboloid mirror which focuses light beam from synchrotron radiation source on entrance slit of Vm-562 vacuum monochromator and homogeneously circular spot appears on focal plane. An ellipsoidal mirror is used to focus spot on exit slit onto sample. It is very difficult to fabrication two aspherical mirror, it is 600 mm from axis, focal length f $EQ 315.7, dimension 40 $MUL 100 mm$+2$/, length of long axis of the ellipsoidal mirror is 1200 mm and that of short axis is 848.52 mm. Al$PLU@MgF$-2$/ layer is coated on the surface mirror. We make use of special fabrication technology and testing method for mirrors and get satisfied with results. Figure error of two mirrors: diameter of circle of diffusion is less than 0.1 mm and surface roughness is less than 1 nm RMS. As it operates at 140 - 400 nm, incidence angle $theta $EQ 45$DGR@, reflectivity of the mirror is better than 75%. These conditions meet requirements for biological spectroscopic experiments in the beamline.!6
机译:摘要:目前同步辐射实验室的光束线3B1。已经建立了北京电子对撞机的实验室,用于软X射线光刻实验。从光束线3B1分支出来的光束3B1B在VUV-VIS上运行,用于生物光谱实验。本文介绍了3B1B光学系统的设计与制造。光学系统设计的特点是采用离轴抛物面镜将来自同步辐射源的光束聚焦在Vm-562真空单色仪的入口狭缝上,并且在焦平面上出现均匀的圆形斑点。椭圆镜用于将狭缝出口上的斑点聚焦到样品上。制造两个非球面镜非常困难,它距轴为600 mm,焦距f $ EQ 315.7,尺寸为40 $ MUL 100 mm $ + 2 $ /,椭球面镜的长轴长度为1200 mm,短轴为848.52毫米。 Al $ PLU @ MgF $ -2 $ /层涂覆在表面镜上。我们利用特殊的制造技术和镜子的测试方法,对结果感到满意。两个反射镜的图形误差:扩散圆的直径小于0.1 mm,表面粗糙度小于1 nm RMS。由于其工作在140-400 nm,入射角$ theta $ EQ 45 $ DGR @,反射镜的反射率优于75%。这些条件满足光束线中生物光谱实验的要求!6

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号