At present day, in the field of lighting the incandescent lamps are phasing out. The solid state lighting products, i.e. LED, and the related market are developing very fast in China for its promising application, due to the energy-saving and the colorful features. For the quality control and the commercial trade purpose, it is highly necessary to measure the optical parameters of LED light sources with a fast, easy and affordable facility. Therefore, more test labs use the spherical spectrometer to measure LED. The quasi- monochrome of LED and the V(lambda) of silicon photodetector mismatch problem is reduced or avoided, because the total spectral radiant flux (TSRF) is measured, and all the optical parameters are calculate from the TSRF. In such a way, the spherical spectrometer calibration requires TSRF standard lamps instead of the traditional total flux standard lamps. National Institute of Metrology China (NIM) has studied and developed the facilities for TSRF measurement and provides related calibration services. This paper shows the TSRF standard lamp calibration procedure using a spherical spectrometer in every-day calibration and its traceable link to the primary SI unit at NIM. The sphere is of 1.5 m diameter, and installed with a spectrometer and a silicon photodetector. It also shows the detail of data process, such as the spectral absorption correction method and the calculation of the result derived from the spectral readings. The TSRF calibration covers the spectra range of 350 ran to 1050 nm, with a measurement uncertainty of3.6%~1.8%(k=2).
机译:目前,在照明领域中,白炽灯正在逐步淘汰。由于其节能和色彩丰富的特点,固态照明产品即LED及其相关市场在中国的发展前景广阔。为了质量控制和商业交易目的,非常需要使用快速,简便和负担得起的设备来测量LED光源的光学参数。因此,更多的测试实验室使用球面光谱仪来测量LED。由于可以测量总光谱辐射通量(TSRF),并且可以从TSRF计算所有光学参数,因此可以减少或避免LED的准单色光和硅光电探测器的V(λ)不匹配问题。这样,球面光谱仪校准需要使用TSRF标准灯,而不是传统的总通量标准灯。中国国家计量研究院(NIM)已研究和开发了用于TSRF测量的设备,并提供了相关的校准服务。本文显示了在日常校准中使用球形光谱仪对TSRF标准灯进行校准的过程,以及可追溯到NIM的主要SI单元的链接。球体直径为1.5 m,并安装了光谱仪和硅光电探测器。它还显示了数据处理的详细信息,例如光谱吸收校正方法以及从光谱读数得出的结果的计算。 TSRF校准涵盖了350 nm至1050 nm的光谱范围,测量不确定度为3.6%〜1.8%(k = 2)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号