We propose here a liquid level sensor using a long period fiber grating (LPFG) in which direct liquid level measurement is carried out by utilising an LPFG, 100mm in length and a periodicity of 1 mm. The LPFG was exposed to liquids with varying levels and the wavelength shift of a selected loss band of the transmission spectra was monitored using a broadband light source and an optical spectrum analyzer. The mechanism of this LPFG sensor is based on the fact that the effective Refractive Index (RI) of a cladding mode is directly dependant on the RI of the surrounding medium, be it air, or in this case water and petrol. As the surrounding RI changes, so does the phase matching condition of the LPFG. The result for the level change of the liquid with a specific RI is both a shift in wavelength and a change in the attenuation level of the selected loss band. For the selected loss band, continuous wavelength shifts of 9.5 nm and 25 nm for 100 mm of water and petrol level change have been observed respectively, with sub-millimetre accuracy.
机译:我们在此提出一种使用长周期光纤光栅(LPFG)的液位传感器,其中通过使用长度为100mm且周期为1mm的LPFG进行直接液位测量。 LPFG暴露于具有不同水平的液体中,并且使用宽带光源和光谱分析仪监控透射光谱的所选损耗带的波长偏移。 LPFG传感器的机理基于这样一个事实,即包层模式的有效折射率(RI)直接取决于周围介质(无论是空气还是在这种情况下为水和汽油)的RI。随着周围RI的变化,LPFG的相位匹配条件也随之变化。具有特定RI的液体的液位变化的结果既是波长的变化,又是所选损耗带的衰减水平的变化。对于选定的损耗带,对于100 mm的水和汽油液位变化,分别观察到9.5 nm和25 nm的连续波长漂移,精度达到了亚毫米。