Preservation of overcurrent relays coordination in microgrids by application of static series compensators

机译:应用静态串联补偿器保持微电网中过流继电器的协调

获取原文
获取原文并翻译 | 示例

摘要

In this paper, the application of static series compensator as a fault current limiter is proposed to preserve the integrity of the overcurrent relays' settings in a microgrid for both modes of operations, i.e., utility-grid connected and autonomous (islanded). Static series compensator could be multiple low-power single-phase inverters that attach to the overhead conductor and dynamically control the line impedance or with the same architecture could control the impedance of the underground cables. The static series compensator would effectively increase the line impedance during faults in order to alleviate the contribution of fault current from the utility-grid, so the fault current does not change appreciably in gird-connected or autonomous modes. The static series compensators are controlled by using customary communication techniques.
机译:在本文中,提出了将静态串联补偿器用作故障电流限制器的应用,以在两种操作模式(即市电并网和自主(孤岛))的微电网中保持过电流继电器设置的完整性。静态串联补偿器可以是多个低功率单相逆变器,它们连接到架空导线并动态控制线路阻抗,或者具有相同的体系结构可以控制地下电缆的阻抗。静态串联补偿器将有效地增加故障期间的线路阻抗,以减轻来自公用电网的故障电流的影响,因此故障电流在并网或自主模式下不会发生明显变化。静态串联补偿器通过使用常规通信技术进行控制。