Power plants use ammonia (or amines) for pH control of the condensate/feedwater circuits andrnhydrazine (or organic substitutes) for oxygen scavenging. Organic amines and oxygen scavengers break downrninto organic acids and carbon dioxide, which increase steam conductivity. This has caused difficulties in attainingrncation conductivity limits in steam during startup, and in many cases after start-up. Experience has shown thatrnswitching to ammonia and hydrazine during the start-up phase improves the chances of attaining the steamrnturbine vendor’s steam quality limits in a shorter time.
机译:发电厂使用氨水(或胺类)控制冷凝水/给水回路的pH,使用肼苯丙胺(或有机替代品)进行除氧。有机胺和氧气清除剂分解为有机酸和二氧化碳,从而增加了蒸汽的传导性。这在启动过程中以及启动后的许多情况下,难以达到蒸汽中的阳离子电导率极限。经验表明,在启动阶段改用氨和肼可以提高在较短的时间内达到汽轮机供应商的蒸汽质量极限的机会。