首页> 外文会议>Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE >Design of trigger test board for the Daya Bay neutrino experiment
【24h】

Design of trigger test board for the Daya Bay neutrino experiment

机译:大亚湾中微子实验触发测试板设计

获取原文

摘要

with a precision down to 1% level at 90% C.L‥ In this experiment, there are three modular detectors, which are located in two near halls and one far hall. The modular detector consists of three types of sub-detectors: the anti-neutrino detector (AD), the water Cherenkov detector (WCD) and the resistive plate chambers (RPC). AD and WCD use the same data readout electronics, including the front end electronic (FEE) and the local trigger board (LTB). To meet the experimental requirement, LTB needs to generate multiple types of triggers with high trigger probabilities. TTB is specially designed to test the LTB performance by generating programmable analog and digital signals required by the LTB. This article shows the design of TTB and the test results of LTB.
机译:在90%C.L‥下,其精度可降至1%的水平。在此实验中,有3个模块化探测器,分别位于两个近厅和一个远厅。模块化探测器由三种类型的子探测器组成:反中微子探测器(AD),切伦科夫水探测器(WCD)和电阻板腔(RPC)。 AD和WCD使用相同的数据读取电子设备,包括前端电子设备(FEE)和本地触发板(LTB)。为了满足实验要求,LTB需要生成具有高触发概率的多种触发类型。 TTB专门设计用于通过生成LTB所需的可编程模拟和数字信号来测试LTB性能。本文介绍了TTB的设计和LTB的测试结果。