Predictability of field airborne noise isolation from laboratory testing

机译:通过实验室测试隔离现场空气传播噪声的可预测性

获取原文
获取原文并翻译 | 示例

摘要

The relationship between laboratory and field noise isolation tests of nominally identicalrnassemblies is a longstanding question in acoustics. Building codes allow field airbornernnoise isolation ratings (ASTC, NIC or NNIC) to be five points lower than therncorresponding laboratory rating (STC), but the origin of this relationship is notrndocumented thoroughly in the literature. Different wood framed floor/ceiling systems wererntested in the laboratory to determine performance prior to implementation in the field.rnField testing was performed in a variety of completed buildings to determine the actualrnacoustical performance of the assemblies that were installed. The results of this testing forrnairborne sound isolation is presented. The authors will present analysis of thernpredictability of field test results based on laboratory test and the apparent translationrnfrom laboratory to field testing.
机译:在名义上相同的组件的实验室和现场噪声隔离测试之间的关系是声学中一个长期存在的问题。建筑法规允许现场空气隔离噪声等级(ASTC,NIC或NNIC)比相应的实验室等级(STC)低五分,但是这种关系的起源在文献中并未得到充分记载。在实验室中对不同的木地板/天花板系统进行了测试,以确定其性能,然后才在现场进行实施。在各种已建成的建筑物中进行了现场测试,以确定所安装组件的实际声学性能。给出了机载空气隔离的测试结果。作者将介绍基于实验室测试的现场测试结果的可预测性分析,以及从实验室到现场测试的明显转换。