Tubular steel jointing system that incorporates prestressed grout sleeve connections rather than conventional bolted or welded connections is an innovation. Research at Monash University in the last 10 years demonstrated that this innovative connection has superior strength under both static and dynamic loading. This paper reports a pilot project investigating the effect of high temperature on the compression capacity of prestressed grout tubular joints. Eleven specimens were tested with different temperatures. The specimens were heated in a furnace and the load was applied through an Instron machine. Three different grout lengths were chosen. The temperatures were measured using thermocouples. The load deflection behaviour at different temperatures was compared. It was found that ultimate load reduces almost linearly as temperature difference between outer and inner tubes increases. It is encouraging to observe the ductile behaviour of grouted joints at elevated temperature.
机译:结合了预应力灌浆套管连接而不是传统的螺栓连接或焊接连接的管状钢连接系统是一项创新。莫纳什大学最近10年的研究表明,这种创新的连接在静态和动态载荷下均具有出色的强度。本文报道了一个试点项目,研究高温对预应力灌浆管接头抗压能力的影响。在不同温度下测试了11个样品。将样品在炉中加热,并通过Instron机器施加载荷。选择了三种不同的灌浆长度。使用热电偶测量温度。比较了不同温度下的载荷挠度行为。已经发现,随着外管和内管之间的温差增加,极限载荷几乎线性减小。在高温下观察灌浆接头的延性是令人鼓舞的。