首页> 外文会议>New development of rotating electrical machines >Study on Internal Cooling Water Quality and Coils Corrosion of Large Generators
【24h】

Study on Internal Cooling Water Quality and Coils Corrosion of Large Generators

机译:大型发电机内部冷却水水质及线圈腐蚀研究

获取原文
获取原文并翻译 | 示例

摘要

In recent years, along with the improvement of manufacture and operation levels of large generating unit, the operation and management levels of large generators internal cooling water are more and more important. As the main editors of the power industry standard DL/T 801? Requirements for internal cooling water quality and It's system in large generators? (revised vision), the authors have researched the problems of large generators internal cooling water occurred in these years. With the increasing of unit capacity and the development of stator coils design and manufacture , the requirement of the large generators internal cooling water quality is higher and higher. This paper takes the quality of large generators internal cooling water for object and researches the blockage fault in stator coils caused by copper corrosion. The authors analyses the reasons of the coils copper corrosion in PH value, oxygen content, conductivity, etc. And it comes to the conclusion that PH value is the main factor on copper corrosion in stator coils. Some suggestions were put forward about the quality of internal cooling water to improve the standard DL/T 801. For example, decrease the copper content, distinguish the PH value between different oxygen contents, delete the index of hardness, modify the value of conductivity on basis of the relationship between conductivity and pH value, etc. (the advises above were adopted in the revised vision of DL/T 801). Meanwhile the question that how to choice the oxygen-poor system or oxygenrich system was discussed in the paper, which shows that the oxygen-rich system isn't always rich in oxygen. And the oxygen-rich system can't work as well as it should be in theory. The paper tries to conclude the views and basis on the process of standard revision. It can help the professionals to understand and execute the new standard. Also it can provide the basis for the operation control of new generator unit internal cooling water and the technical transformation of old generator units.
机译:近年来,随着大型发电机组的制造和运行水平的提高,大型发电机内部冷却水的运行和管理水平越来越重要。作为电力行业标准DL / T 801的主要编辑?对内部冷却水质量的要求及其在大型发电机中的系统? (修订版),作者研究了近年来大型发电机内部冷却水的问题。随着单位容量的增加和定子线圈设计制造的发展,对大型发电机内部冷却水水质的要求越来越高。本文以大型发电机内部冷却水的质量为对象,研究了由于铜腐蚀引起的定子线圈堵转故障。从PH值,氧含量,电导率等方面分析了线圈铜腐蚀的原因。得出结论,PH值是影响定子线圈铜腐蚀的主要因素。针对内部冷却水的质量提出了一些建议,以提高标准DL / T801。例如,降低铜含量,区分不同氧含量之间的PH值,​​删除硬度指标,修改导电率等。电导率和pH值之间的关系等基础(在DL / T 801的修订版中采用了上述建议)。同时,本文讨论了如何选择贫氧系统或富氧系统的问题,这表明富氧系统并不总是富含氧气。富氧系统无法正常运行,在理论上应该如此。本文力图总结对标准修订过程的看法和依据。它可以帮助专业人员理解和执行新标准。也可为新发电机组内部冷却水的运行控制和旧发电机组的技术改造提供依据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号