Alloy 22 (Ni-22Cr-13Mo-3Fe-3W) is a candidate alloy for nuclear materials storage containers in the Yucca Mountain High Level Nuclear Waste Repository as well as for sub-surface applications. In this study, we present the results of our investigation on the corrosion behavior of Alloy 22 as a function of temperature simulated Yucca Mountain (YM) water in deaerated/aerated conditions. Standard electrochemical potentiodynamic tests have been used to determine the passivation behavior of Alloy 22 in simulated YM water. Our results show that, at room temperature, the passive current density for Alloy 22 in aerated conditions was 5×10-7 A.cm-2 compared to 2×10-6 A.cm-2 in deaerated YM water, suggesting aeration is conducive to formation of passive films (that inhibit the corrosion process). Results from Potentiodynamic studies, Scanning Electron Microscope (SEM) coupled with Energy Dispersive X-Ray Microanalysis (EDX) to characterize the passive film at room temperature and at different applied potential are presented.
机译:合金22(Ni-22Cr-13Mo-3Fe-3W)是用于尤卡山高等级核废料储存库中的核材料储存容器以及地下应用的候选合金。在这项研究中,我们提出了在脱气/充气条件下,作为温度模拟丝兰山(YM)水的函数对22号合金腐蚀行为进行调查的结果。已使用标准电化学势力学测试来确定合金22在模拟YM水中的钝化行为。我们的结果表明,在室温下,合金22在充气条件下的无源电流密度为5×10-7 A.cm-2,而在脱气的YM水中为2×10-6 A.cm-2,这表明通气是有利于形成钝化膜(抑制腐蚀过程)。提出了电位动力学研究,扫描电子显微镜(SEM)结合能量色散X射线显微分析(EDX)来表征室温和不同施加电势下的钝化膜的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号