There are several ophthalmic devices to image the retina, from fundus cameras capable to image the whole fundus to scanning ophthalmoscopes with photoreceptor resolution. Unfortunately, these devices are prone to a variety of ocular conditions like defocus and media opacities, which usually degrade the quality of the image. Here, we demonstrate a novel approach to image the retina in real-time using a single pixel camera, which has the potential to circumvent those optical restrictions. The imaging procedure is as follows: a set of spatially coded patterns is projected rapidly onto the retina using a digital micro mirror device. At the same time, the inner product's intensity is measured for each pattern with a photomultiplier module. Subsequently, an image of the retina is reconstructed computationally. Obtained image resolution is up to 128 x 128 px with a varying real-time video framerate up to 11 fps. Experimental results obtained in an artificial eye confirm the tolerance against defocus compared to a conventional multi-pixel array based system. Furthermore, the use of a multiplexed illumination offers a SNR improvement leading to a lower illumination of the eye and hence an increase in patient's comfort. In addition, the proposed system could enable imaging in wavelength ranges where cameras are not available.
机译:从能够对整个眼底成像的眼底照相机到具有感光器分辨率的扫描检眼镜,有几种眼科设备可以对视网膜成像。不幸的是,这些设备易于出现各种眼病,例如散焦和介质不透明,这通常会降低图像质量。在这里,我们演示了一种使用单像素相机实时成像视网膜的新颖方法,它有可能规避那些光学限制。成像过程如下:使用数字微镜设备将一组空间编码的图案快速投影到视网膜上。同时,使用光电倍增模块测量每种图案的内积强度。随后,通过计算重建视网膜图像。所获得的图像分辨率高达128 x 128 px,实时视频帧率高达11 fps。与传统的基于多像素阵列的系统相比,在人造眼睛中获得的实验结果证实了对散焦的耐受性。此外,使用多路照明可以改善SNR,从而降低眼睛的照明度,从而提高患者的舒适度。另外,提出的系统可以在没有相机的波长范围内成像。

著录项

  • 来源
    《Multimodal biomedical imaging XII》|2017年|100570M.1-100570M.7|共7页
  • 会议地点 San Francisco(US)
  • 作者单位

    Laboratorio de Optica, Campus Espinardo, Universidad de Murcia, 30100 Murcia, Spain;

    Laboratorio de Optica, Campus Espinardo, Universidad de Murcia, 30100 Murcia, Spain;

    Laboratorio de Optica, Campus Espinardo, Universidad de Murcia, 30100 Murcia, Spain;

    Institute of New Imaging Technologies, Universitat Jaume I, 12006 Castellon, Spain;

    Institute of New Imaging Technologies, Universitat Jaume I, 12006 Castellon, Spain;

    Institute of New Imaging Technologies, Universitat Jaume I, 12006 Castellon, Spain;

    Laboratorio de Optica, Campus Espinardo, Universidad de Murcia, 30100 Murcia, Spain;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    ophthalmoscope; fundus camera; single pixel camera; computational imaging;

    机译:检眼镜眼底照相机单像素相机;计算成像;;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号