The quick transmission of radiological data between Medical Treatment Facilities (MTFs) greatly determines the quality of care a wounded soldier receives. A typical full-body Computed Tomography (CT) study currently takes on average 4.5 hours to be transmitted from one MTF to another while a single digital chest x-ray can take over an hour. An evacuated wounded soldier often arrives at the higher-level MTF before the images sent by the lower-level MTF are received, impacting greatly the ability to receive proper and potentially lifesaving medical treatment. This study examines via modeling and simulation the transmission times of CT, X-ray, and ultrasound images between MTFs within IRAQ while varying the number of available satellite channels, adding broadband Line-of-Site (LOS) connectivity, and Hub-Spoke vs. Mesh satellite topologies - all against a goal of total image transmission time of 15 minutes or less for a 250 MB full-body CT study.
机译:放射数据在医疗机构之间的快速传输极大地决定了受伤士兵的护理质量。目前,一项典型的全身计算机断层扫描(CT)研究平均需要4.5小时才能从一个MTF传输到另一个MTF,而单个数字胸部X射线可能需要一个多小时。疏散的受伤士兵经常在下级MTF发送的图像被接收之前到达上级MTF,这极大地影响了接受适当且可能挽救生命的医疗的能力。这项研究通过建模和仿真研究了IRAQ中MTF之间CT,X射线和超声图像的传输时间,同时改变了可用卫星频道的数量,增加了宽带站点线(LOS)连接,以及中心辐射与网状卫星拓扑-所有目标都是针对250 MB全身CT研究的总图像传输时间不超过15分钟。