The authors focused on the problems of measurement of attenuation and homogeneity of special fibers of polydimethylsiloxane (PDMS) depending on three different procedures for mixing PDMS and curing agent. We used a two-component elastomer Sylgard 184. For mixing was used a defined ratio of 10:1 for PDMS, which was determined based on the datasheet. Curing of samples took place in a heat box at a constant temperature of 80 ℃ ± 3 ℃. Three procedures were defined for mixing PDMS and curing agent: manual, using a laboratory shaker and ultrasonic baths. For each method of mixing was carried out a total of 25 samples. The test samples have a defined shape in the form of a cylindrical waveguide with a diameter of 5 mm and a length of 50 mm. The whole process of production of cylindrical waveguides applied in the protective vacuum box. To verify the homogeneity of the samples were divided into 5 mm sections, measured was the attenuation constant in both directions. As a source of radiation was used LED (Light Emitting Diode) with a wavelength of 470 nm. The outcome of this study is the evaluation of the quality waveguides by the size of the total attenuation and the attenuation constant for analysis of spreading out in homogeneities depending on the procedure of mixing PDMS and curing agent. The analysis performed with regarding the use of PDMS for its optical properties.
机译:作者着重于测量聚二甲基硅氧烷(PDMS)特殊纤维的衰减和均匀性的问题,这取决于将PDMS和固化剂混合的三种不同程序。我们使用了两组分弹性体Sylgard184。为混合使用的PDMS的定义比例为10:1,这是根据数据表确定的。样品的固化在加热箱中于80℃±3℃的恒定温度下进行。定义了三种混合PDMS和固化剂的程序:使用实验室振荡器和超声浴的手动程序。对于每种混合方法,总共进行25个样品。测试样品具有圆柱形波导形式的限定形状,直径为5mm,长度为50mm。在保护真空箱中应用圆柱形波导的整个生产过程。为了验证样品的均质性,将其分为5毫米的部分,测量两个方向的衰减常数。作为辐射源,使用波长为470nm的LED(发光二极管)。这项研究的结果是根据总衰减的大小和衰减常数对质量波导进行评估,以便根据PDMS和固化剂的混合过程来分析均匀性的扩展。关于使用PDMS的光学特性进行了分析。

著录项

  • 来源
    《Micro-structured and specialty optical fibres V》|2017年|102320o.1-102320o.6|共6页
  • 会议地点 Prague(CZ)
  • 作者单位

    VSB - Technical university of Ostrava, Faculty of Electrical Engineering and Computer Science, Department of Telecommunications, 17. listopadu 15, 708 33 Ostrava, Czech Republic;

    VSB - Technical university of Ostrava, Faculty of Electrical Engineering and Computer Science, Department of Telecommunications, 17. listopadu 15, 708 33 Ostrava, Czech Republic;

    VSB - Technical university of Ostrava, Faculty of Electrical Engineering and Computer Science, Department of Telecommunications, 17. listopadu 15, 708 33 Ostrava, Czech Republic;

    VSB - Technical university of Ostrava, Faculty of Electrical Engineering and Computer Science, Department of Telecommunications, 17. listopadu 15, 708 33 Ostrava, Czech Republic;

    VSB - Technical university of Ostrava, Faculty of Electrical Engineering and Computer Science, Department of Telecommunications, 17. listopadu 15, 708 33 Ostrava, Czech Republic;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Polydimethylsiloxane; PDMS; Attenuation; Homogeneity; Sylgard 184;

    机译:聚二甲基硅氧烷; PDMS;衰减;同质性西尔加德184;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号