摘要

Due to increasing requirements the quality of wastewater treatment plant effluent is improving. Therefore, further treatment and reuse of effluent became effective and beneficial. One of the techniques to improve effluent is dead-end membrane ultrafiltration (UF). During UF, foulant remain on the membrane and causes decline in flux. The decline in flux related to the time is called filterability. The fouling is regularly removed by a flush in the opposite direction i.e. backflush (BF) to recover the flux. The recovery of the flux is called reversibility. To get more insight into the filterability Roorda (2004) designed the Specific Ultrafiltration Resistance (SUR) test. This test determines the filterability of effluent in 30 minutes. The objective of this research is to extend the SUR with a BF to determine the reversibility in a fast way as well. Therefore the SUR~+ is developed. This paper focuses on the investigation of different process conditions of the SUR~+test, to make it representative to full scale UF. The experiments revealed that the BF pressure must be similar to the filtration pressure (used during filterability determination) which is 0.5 bar. The backflush duration must be at least 30 seconds to remove all reversible fouling. A final adjustment to the SUR~+ setup, enables to backflush with permeate collected during the filterability determination.
机译:由于需求增加,废水处理厂废水的质量正在提高。因此,废水的进一步处理和再利用变得有效和有益。改善废水的技术之一是死膜超滤(UF)。在超滤过程中,污垢残留在膜上并导致通量下降。与时间有关的通量下降称为可过滤性。定期通过反方向冲洗(即反冲洗(BF))来清除结垢,以回收焊剂。通量的恢复称为可逆性。为了更深入地了解可过滤性,Roorda(2004)设计了比抗超滤性(SUR)测试。该测试确定了30分钟内废水的可过滤性。这项研究的目的是通过BF扩展SUR,以快速确定可逆性。因此开发了SUR〜+。本文着重研究SUR〜+测试的不同工艺条件,以使其代表全尺寸超滤。实验表明,高炉压力必须类似于过滤压力(在确定可过滤性时使用)0.5 bar。反吹持续时间必须至少为30秒,以消除所有可逆的积垢。对SUR〜+设置进行最终调整,可以用可过滤性确定期间收集的渗透液进行反冲洗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号