In this paper, experimental verification of the loss reduction method on substrate integrated suspended line (SISL) platform is given. The strategy of reducing the total circuit loss, including the radiation loss, the conductor loss, and the dielectric loss based on SISL platform is given. The experimental verifications and comparisons have demonstrated the effectiveness of the proposed loss reduction method. The implemented 3-dB SISL patch coupler has a total loss reduction of 87.5%, and the loss is much smaller as compared with the state of art.
机译:在本文中,给出了衬底集成悬挂管线(SISL)平台上的损失减少方法的实验验证。给出了减少总电路损耗的策略,包括基于SISL平台的辐射损失,导体损耗和介电损耗。实验验证和比较已经证明了拟议的损失减少方法的有效性。实施的3-DB SISL贴片耦合器的总损失减少87.5%,与现有技术相比,损耗远小得多。