首页> 外文会议>International Specialty Conference on Cold-Formed Steel Structures >Experimental investigation into the behaviour of back-to-back gapped built-up cold-formed steel channel sections under compression
【24h】

Experimental investigation into the behaviour of back-to-back gapped built-up cold-formed steel channel sections under compression

机译:压缩下背靠背内置冷成型钢通道部分的实验研究

获取原文

摘要

Back-to-back gapped built-up cold-formed steel channel-sections are used as compression members in cold-formed steel structures, such as trusses, space frames and portal frames etc. Because of the complex and non-uniform cross section of the back-to-back gapped built- up cold-formed steel channel columns, it is difficult to calculate the strength of these sections accurately. Current guidance by the direct strength method in the AISI Specification and the Australian/New Zealand Standard doesn't include the gap between the back-to-back channels, thus not being able to predict the axial capacities of these sections accurately. In the literature, very few results have been reported for such columns and specially investigated the effect of link-channel's spacing on axial strength of such columns. This issue is addressed herein. Forty new experimental results are reported, conducted on back-to-back gapped built-up cold-formed steel channel-sections, covering stub to slender columns. Axial capacity of the columns, load-axial shortening, load-axial strain, failure modes and deformed shapes were observed and reported in this paper. Also, the effect of link-channel's spacing on axial strength, is investigated. Test strengths are compared against the design strengths calculated in accordance with AISI and Australian/New Zealand standard for cold-formed steel structures. It is shown that the design standards can be conservative by as much as 53%, while predicting axial strength of such columns. Therefore, a modification to the non-dimensional slendemess, that considers the gap, is proposed which leads the design standards being within 5% conservative to the test results.
机译:背靠背的覆盖层内置的冷成型钢通道部分用作冷成型钢结构中的压缩构件,例如桁架,空间框架和门栅等。由于复杂和不均匀的横截面背靠背的覆盖层内置的冷成型钢通道柱,很难准确地计算这些部分的强度。 AISI规范中的直接强度法的当前指导和澳大利亚/新西兰标准不包括背对背通道之间的间隙,从而能够精确地预测这些部分的轴向容量。在文献中,据报道了这些柱的几乎没有结果,并特别研究了链路通道间距对这些柱的轴向强度的影响。此问题在此处解决。报告了四十个新的实验结果,在背靠背的覆盖内置的冷成型钢通道部分进行,覆盖柱覆盖柱。在本文中观察并报道了柱子,负荷轴向缩短,负载轴向应变,故障模式和变形形状的轴向容量。而且,研究了链路通道的间距对轴向强度的影响。比较测试强度与根据AISI和澳大利亚/新西兰的冷成型钢结构标准计算的设计强度。结果表明,设计标准可以保守高达53%,同时预测这种柱的轴向强度。因此,提出了考虑间隙的非维度裂缝的修改,这引发了设计标准在5%内保守测试结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号