首页> 外文会议>IEEE Conference on Systems, Process Control >Energy performance and feasibility study for Thermal Energy Storage (TES) System at engineering complex UiTM Shah Alam
【24h】

Energy performance and feasibility study for Thermal Energy Storage (TES) System at engineering complex UiTM Shah Alam

机译:工程综合体综合体储存(TES)系统的能量绩效与可行性研究

获取原文

摘要

This paper presents an energy performance and feasibility study of Thermal Energy Storage (TES) System compared with direct supply system of chilled water to an engineering complex in UiTM. In principle, TES system is a load management technology which shift load from peak to off-peak utility periods thus reduces maximum demand of electrical needs during the day and takes advantage of the low off peak tariff offered by the utility company (TNB). Data of a month's load profile was analysed and it was found that the TES system consumed more energy by 27% compared to the direct supply system of chilled water but its maximum demand reduced by 23%. The estimated cost (RM) per day was less by only 4%, under no energy loss, due to the introduction of thermal energy storage system compared with the direct system. Under the current electricity tariff, TES system in Malaysia is not feasible economically. However, if the maximum demand electrical tariff is revised the TES system can be attractive.
机译:本文介绍了热能储存(TES)系统的能量性能和可行性研究,与UITM中的工程综合体的直接供应系统相比。原则上,TES系统是一种负载管理技术,其峰值从峰值转移到非峰值实用程序时期,因此在白天减少了电气需求的最大需求,并利用公用事业公司(TNB)提供的低离峰峰值关税。分析了一个月的负载曲线的数据,并发现与冷冻水的直接供应系统相比,TES系统将更多的能量减少27%,但其最大需求降低了23%。由于与直接系统相比,由于引入热能储存系统,因此每天每天的估计成本(RM)均小于4%。在目前的电力关税下,马来西亚的TES系统在经济上不可行。但是,如果修订最大需求电关税,则TES系统可能具有吸引力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号