首页> 外文会议>International Conference on Applied Superconductivity and Electromagnetic Devices >Heat Leakage Measurement of Energy Pipeline Current Leads by Temperature Gradient Method
【24h】

Heat Leakage Measurement of Energy Pipeline Current Leads by Temperature Gradient Method

机译:通过温度梯度法对能量管线电流引线进行热泄漏测量

获取原文

摘要

Current lead is the main heat source of HTS cable. As a new type of hybrid HTS cable, the heat leakage of current lead in superconducting energy pipeline directly affects the system efficiency. In this paper, the optimum design method of the current lead was briefly introduced. To verify and test the designed current lead, a heat leakage measurement platform was built. The platform is based on the temperature gradient method, which reduces the requirement of sealing and thermal insulation performance of the system. Simulation and test results show that the platform has the advantages of fast and accurate, which can meet the needs of current lead heat leakage measurement.
机译:电流铅是HTS电缆的主要热源。作为一种新型的混合HTS电缆,超导能量管道中电流引线的热泄漏直接影响了系统效率。本文简要介绍了当前引线的最佳设计方法。为了验证和测试设计的电流铅,构建了散热测量平台。该平台基于温度梯度法,这减少了系统的密封和保温性能的要求。仿真和测试结果表明,该平台具有快速准确的优点,可满足当前铅散热测量的需求。