首页> 外文会议>Annual Water Environment Federation technical exhibition and conference >Emissions Control for Digester Gas-fired Internal Combustion Engines at Wastewater Treatment Plants
【24h】

Emissions Control for Digester Gas-fired Internal Combustion Engines at Wastewater Treatment Plants

机译:废水处理厂蒸煮器气体内燃机的排放控制

获取原文

摘要

The Orange County Sanitation District (OCSD) owns and operates two wastewater treatment plants (WWTPs) with large digester gas-fired internal combustion (IC) engines. Plant 1 has three (3) 2.5 megawatt (MW) IC engines and Plant 2 has five (5) 3 MW IC engines, fueled primarily by digester gas (biogas) and supplemented by natural gas. The IC engines are required to comply with South Coast Air Quality Management District (SCAQMD) Rule 1110.2 for stationary IC engines. On Feburary1, 2008, SCAQMD amended Rule 1110.2 to require biogas gas fired engines to meet stringent emission limits for NOx (11 ppmvd), CO (250 ppmvd) and VOC to (30 ppmvd) at 15 % oxygen by July 1, 2012. OCSD is performing a full scale demonstration project to determine the technical and cost feasibilities of meeting the future emission limits. The project includes a digester gas cleaning system using carbon media for removal of siloxanes and other harmful contaminants from the digester gas and a post combustion control using an oxidative catalyst for controlling of CO and VOCs emissions and a selective catalytic reduction (SCR) system with urea injection for controlling of NOx emissions. Emissions of CO, NOx, VOCs and air toxics are monitored at the inlet and outlet of the catalytic oxidizer/SCR system. The full scale system commenced operation in April 2010 and is being monitored for overall performance. SCAQMD provided partial funding for this demonstration project since the information will be used to support rulemaking decisions. SCAQMD will use the findings of this study along with other demonstration projects to finalize the Rule 1110.2 requirements for biogas fired IC engines. The results of the data collected for the demonstration project showed that the system can meet the average emissions limits of NOx, CO and VOC of 11, 250 and 30 ppmvd at 15% oxygen, respectively. Further evaluations are being performed to determine if the control system can meet the emission limits under all operating scenarios such as start up, shut down, changing loads and fuel blends. Currently, the control system is operating on the initial catalysts installed during startup and no catalyst has been replaced. Cost effectiveness of the project was developed after the system has operated for over one year. Depending on SCAQMD final rulemaking decisions, the results of the overall demonstration project may have a significant cost impact to operators of biogas fired IC engines in southern California.
机译:橙县卫生区(OCSD)拥有并经营两种废水处理厂(WWTPS),带有大型蒸煮燃气的内燃机(IC)发动机。工厂1具有三(3)兆瓦(MW)IC发动机和工厂2拥有五(5)个3兆瓦的IC发动机,主要由Decester Gas(沼气)加油,并通过天然气补充。 IC发动机必须遵守南海岸空气质量管理区(SCAQMD)规则1110.2为固定IC发动机。在Febebarary1,2008上,SCAQMD修订了第1110.2条规则1110.2要求沼气燃气发动机在2012年7月1日之前以15%氧气(30 ppmvd),CO(250ppmvd)和VOC的严格排放限值,以2012年7月1日。OCSD正在执行全规模示范项目,以确定满足未来排放限制的技术和成本。该项目包括使用碳培养基的蒸煮气体清洁系统,用于从蒸煮气体中除去硅氧烷和其他有害污染物,并使用氧化催化剂来控制CO和VOCS排放和具有尿素的选择性催化还原(SCR)系统注射用于控制NOx排放。在催化氧化剂/ SCR系统的入口和出口处监测CO,NOx,VOC和AIR TOXICS的排放。全规模系统于2010年4月开始运营,正在监测整体性能。 SCAQMD为此示范项目提供了部分资金,因为该项目将用于支持规则​​制定决策。 SCAQMD将使用本研究的调查结果以及其他演示项目来最终确定沼气射击IC发动机的规则1110.2要求。为演示项目收集的数据结果表明,该系统可以分别满足11,250和30 ppmVd的NOx,CO和VOC的平均排放限值。正在执行进一步的评估以确定控制系统是否可以在所有操作场景下满足排放限制,例如启动,关闭,更换负载和燃料混合。目前,控制系统正在启动期间安装的初始催化剂,并且没有催化剂已被更换。该项目的成本效益在系统运营一年后开发。根据SCAQMD最终规划决策,整体示范项目的结果可能对南加州沼泽射击IC发动机的运营商产生重大成本影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号