An efficient autofocus algorithm for indirect immunofluorescence applications

机译:一种高效的自检应用于间接免疫荧光应用

获取原文

摘要

Photobleaching effect is a major issue in developing autofocus algorithms for indirect immunofluorescence (IIF) assay since it quickly flattens the fluorescence intensity of the samples. To overcome this limitation we propose an autofocus algorithm, suited for IIF, aiming at minimizing the number of images required to focus the sample. We test our algorithm with an heterogeneous set of IIF images containing the substrates most widely used in clinical practice, comparing popular focus functions in order to find out the most appropriate for our procedure. Experimental results prove that our algorithm focus the sample using less images than other popular algorithms proposed in the literature.
机译:PhotoBlaching Effects是开发间接免疫荧光(IIF)测定的自动对焦算法的主要问题,因为它迅速达到样品的荧光强度。为了克服这种限制,我们提出了一种自动对焦算法,适用于IIF,旨在最小化将样本所需的图像数量最小化。我们用临床实践中最广泛使用的基板的异构IIF图像测试我们的算法,比较流行的焦点函数,以便找出最合适的程序。实验结果证明,我们的算法将样本聚焦使用的图像比文献中提出的其他流行算法。