Experimental determination of wind loads on 200 m tall three-tower blocks

机译:200 m高三塔楼的风荷载的实验确定

获取原文
获取原文并翻译 | 示例

摘要

A ease study of wind tunnel investigation on pressure measurement on a 200m tall tower block with an irregular plan shape was carried out. The study has clearly brought the need to include the torsional loading. Based on the test results, a mean force coefficient of 1.65 in the along-wind direction and a coefficient of 1,0 in the across-wind direction with an eccentricities of +- 0.1B is recommended for the design. The effect of interference due to adjacent two similar towers is also reported.
机译:对平面形状不规则的200m高塔楼的压力测量进行风洞调查的简易性研究。该研究显然提出了将扭转载荷包括在内的需要。根据测试结果,建议在顺风方向的平均力系数为1.65,在偏风方向的平均力系数为1,0,偏心率为±0.1B。还报告了由于相邻的两个相似塔造成的干扰影响。