STARTUP AND SHUTDOWN STEAM GENERATOR SEPARATOR PIPING FORCES FOR A COAL-FIRED SUPERCRITICAL POWER PLANT

机译:用于燃煤超临界电厂的启动和关机蒸汽发生器分离器管道

获取原文

摘要

Coal-fired supercritical power plants have steam generator liquid/vapor separator systems used during transition to/from "drum" mode and "once-through" mode, which undergo flow transients, involving control systems and valve openings, during startup and shutdown. These transients result in fluid acceleration which can produce significant reaction loads on piping systems (20 kips or higher). The evaluation of these loads is used to design piping supports and to assess possible control system and valving modifications. The computation of these transient loadings is challenging because the conditions in steam generator separator systems range from supercritical to subcritical, two phase, cold water or steam conditions occurring over a wide range of pressures and valve operating characteristics. A transient analysis of a typical separator-condensate line is performed using computer codes RELAP5/MOD3.2 and R5FORCE for the hydrodynamic force-time history. A range of hydraulic loads associated with a range of operating conditions is provided in this paper using different boundary conditions for separator tank pressure, initial temperature of water in pipe lines, and control valve opening/closing times. These sensitivity runs show the benefit of plant control system changes to prevent the control valves opening above 1400 psia, increasing the control valve opening time to over one second, and the effects of keeping the separator-condensate line hot.
机译:燃煤超临界发电厂具有蒸汽发生器液/蒸汽分离器系统,其在转换到/从“滚筒”模式和“一次性”模式,这在启动和关闭期间涉及控制系统和阀门开口的流动瞬变。这些瞬变导致流体加速,可以在管道系统(20 kips或更高)上产生显着的反应载荷。对这些负载的评估用于设计管道支撑件,并评估可能的控制系统和阀门修改。这些瞬态载荷的计算是具有挑战性的,因为蒸汽发生器分离器系统中的条件范围从超临界到亚临界,两相,冷水或蒸汽条件发生在各种压力和阀门操作特性上。使用计算机代码Relap5 / Mod3.2和R5Force进行典型分离器 - 冷凝物线的瞬态分析,用于流体动力学力 - 时间历史。本文在本文中提供了一系列与一系列操作条件相关的液压负载,用于分离罐压力,管线中的水的初始温度,以及控制阀打开/闭合时间的不同边界条件提供。这些灵敏度运行显示了工厂控制系统的益处,以防止控制阀在1400psia上方开口,将控制阀打开时间增加到一秒钟,以及保持分离器冷凝水的效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号