首页> 外文会议>Conference on physics of medical imaging >A clinical evaluation of total variation-stokes image reconstruction strategy for low-dose CT imaging of the chest
【24h】

A clinical evaluation of total variation-stokes image reconstruction strategy for low-dose CT imaging of the chest

机译:胸部低剂量CT成像的总变异ZOORE图像重建策略的临床评价

获取原文

摘要

One hundred "normal-dose" computed tomography (CT) studies of the chest (i.e., 1,160 projection views, 120kVp, 100mAs) data sets were acquired from the patients who were scheduled for lung biopsy at Stony Brook University Hospital under informed consent approved by our Institutional Review Board. To mimic low-dose CT imaging scenario (i.e., sparse-view scan), sparse projection views were evenly extracted from the total 1,160 projections of each patient and the total radiation dose was reduced according to how many sparse views were selected. A standard filtered back-projection (FBP) algorithm was applied to the 1160 projections to produce reference images for comparison purpose. In the low-dose scenario, both the FBP and total variation-stokes (TVS) algorithms were applied to reconstruct the corresponding low-dose images. The reconstructed images were evaluated by an experienced thoracic radiologist against the reference images. Both the low-dose reconstructions and the reference images were displayed on a 4-megapixel monitor in soft tissue and lung windows. The images were graded by a five-point scale from 0 to 4 (0, non-diagnostic; 1, severe artifact with low confidence; 2, moderate artifact or moderate diagnostic confidences; 3, mild artifact or high confidence; 4, well depicted without artifacts). Quantitative evaluation measurements such as standard deviations for different tissue types and universal quality index were also studied and reported for the results. The evaluation concluded that the TVS can reduce the view number from 1,160 to 580 with slightly lower scores as the reference, resulting in a dose reduction to close 50%.
机译:从被告知同意的核查公司预定在STONY Brook University医院安排肺活检的患者中获取胸部(即1,160投影观点,120kVP,100mas)数据集的一百个“正常剂量”计算断层扫描(CT)研究。我们的机构审查委员会。为了模仿低剂量CT成像场景(即,稀疏视图扫描),稀疏投影视图从每位患者的总量1,160突出量均匀提取,并且根据选择了多少稀疏视图,减少了总辐射剂量。将标准滤波后投影(FBP)算法应用于1160突起以产生用于比较目的的参考图像。在低剂量场景中,FBP和总变化 - 斯托克斯(TVS)算法都被应用于重建相应的低剂量图像。通过经验丰富的胸部放射科医师对参考图像评估重建的图像。低剂量重建和参考图像都显示在软组织和肺窗中400万像素的监视器上。从0到4(0,非诊断; 1,严重的伪像,低置信度; 2,适度的伪像或中度诊断信心; 3,温和的神器或高度置信度; 4,良好的施用;没有伪影)。还研究了定量评估测量,例如不同组织类型和普遍质量指标的标准偏差,并报告结果。评估得出结论,电视可以将1,160到580的视图号减少,分数略低于参考,导致剂量降低以关闭50%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号