首页> 外文会议>Conference on physics of medical imaging >Estimation of adipose compartment volumes in CT images of a mastectomy specimen
【24h】

Estimation of adipose compartment volumes in CT images of a mastectomy specimen

机译:乳房切除术样标本CT图像中脂肪盒体积的估计

获取原文

摘要

Anthropomorphic software breast phantoms have been utilized for preclinical quantitative validation of breast imaging systems. Efficacy of the simulation-based validation depends on the realism of phantom images. Anatomical measurements of the breast tissue, such as the size and distribution of adipose compartments or the thickness of Cooper's ligaments, are essential for the realistic simulation of breast anatomy. Such measurements are, however, not readily available in the literature. In this study, we assessed the statistics of adipose compartments as visualized in CT images of a total mastectomy specimen. The specimen was preserved in formalin, and imaged using a standard body CT protocol and high X-ray dose. A human operator manually segmented adipose compartments in reconstructed CT images using ITK-SNAP software, and calculated the volume of each compartment. In addition, the time needed for the manual segmentation and the operator's confidence were recorded. The average volume, standard deviation, and the probability distribution of compartment volumes were estimated from 205 segmented adipose compartments. We also estimated the potential correlation between the segmentation time, operator's confidence, and compartment volume. The statistical tests indicated that the estimated compartment volumes do not follow the normal distribution. The compartment volumes are found to be correlated with the segmentation time; no significant correlation between the volume and the operator confidence. The performed study is limited by the mastectomy specimen position. The analysis of compartment volumes will better inform development of more realistic breast anatomy simulation.
机译:拟蒽醛软件乳房映像已被用于乳房成像系统的临床前定量验证。基于模拟的验证的功效取决于幻影图像的现实主义。乳腺组织的解剖学测量,例如脂肪盒的尺寸和分布或Cooper韧带韧带的厚度,对于乳房解剖学的现实模拟至关重要。然而,在文献中,这种测量不容易获得。在这项研究中,我们评估了在总乳房切除术样标本的CT图像中可视化的脂肪隔室的统计数据。将样品保存在福尔马林中,并使用标准体CT协议和高X射线剂量进行成像。人工操作者使用ITK-SNAP软件在重建的CT图像中手动分割脂肪隔室,并计算每个隔间的体积。此外,记录了手动分割和操作员信心所需的时间。从205个分段的脂肪隔室估计隔室体积的平均体积,标准偏差和概率分布。我们还估计了分割时间,运营商的置信度和隔间体积之间的潜在相关性。统计测试表明,估计的隔室体积不遵循正态分布。发现隔间卷与分割时间相关;体积与运营商信心之间没有显着相关性。进行的研究受乳房切除标本位置的限制。隔室卷分析将更好地提供更现实的乳房解剖模拟的发展。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号