首页> 外文会议>Conference on Biomedical diagnostic, guidance, and surgical-assist systems >Quantitative muscle oxygenation measurement using NIRS with correction for the influence of a fat layer: comparison of oxygen consumption rates with measurements by other techniques
【24h】

Quantitative muscle oxygenation measurement using NIRS with correction for the influence of a fat layer: comparison of oxygen consumption rates with measurements by other techniques

机译:使用NIRS进行定量肌肉氧合测量,使用脂肪层的影响校正:氧消耗率与其他技术的测量比较

获取原文

摘要

The inhomogeneity of tissue structure greatly affects the sensitivity of tissue oxygenation measurement by near-IR spectroscopy (NIRS). We have proposed a method for correcting the influence of a subcutaneous fat layer on muscle oxygenation measurements. In this study, we validated our correction method by measuring oxygen consumption rates of the forearm muscle and comparing the measurements with those obtained by other techniques. $+31$/P-magnetic resonance spectroscopy and positron emission tomography (PET). In NIRS, Vo$-2$/mus was obtained from the falling rate of oxygenation in ischaemia tests. The values of Vo$- 2$/mos were corrected using a curve of measurement sensitivity against fat layer thicknesses, which were measured by ultrasonography. The corrected Vo$-2$/mus showed greater values and less variation between individuals than did the uncorrected one. In the $+31$/P-NMR measurements on 10 subjects, Vo$-2$/mus was estimated from changes in phosphocreatine. The corrected Vo$-2$/mus in NIRS correlated well with the measurements by $+31$/P-NMR compared to the uncorrected Vo$-2$/mus. This result suggested that our correction method is valid. Vo$-2$/mus was also measured using PET in one of the authors. The measured values by NIRS. $+31$/P-NMR and PET were 0.22, 0.17, 0.24 ml 100g$+$MIN@1$/ min$+$MIN@1$/, respectively. The measurement by NIRS using our correction method was in an acceptable range.
机译:组织结构的不均匀性极大地影响了近红外光谱(NIRS)的组织氧合测量的敏感性。我们提出了一种校正皮下脂肪层对肌肉氧合测量的影响的方法。在这项研究中,我们通过测量前臂肌肉的氧气消耗率并将测量与其他技术获得的测量进行比较来验证我们的校正方法。 $ + 31 $ / p磁共振光谱和正电子发射断层扫描(PET)。在NIRS中,vo $ -2 $ / mU是从溶血性氧气的下降率获得的。使用对脂肪层厚度的测量敏感性的曲线来校正Vo $-2 $ / MOS的值,该曲线通过超声检查测量。纠正的vo $ -2 $ / mus在未校正的vo $-$ -2 $ / mus显示出更大的价值观,而不是未校正的价值观。在10个受试者的$ + 31 $ / p-NMR测量中,VO $ -2 $ / MU是磷酸化的变化估计。与未校正的VO $-2 $ / MU值相比,NIR中的校正VO $ -2 $ / MUS与次数+ 31美元/ p-NMR相关。这结果表明我们的校正方法有效。 vo $ -2 $ / mus也在其中一位作者中使用PET测量。 nirs的测量值。 $ + 31 $ / p-nmr和PET为0.22,0.17,0.24 ml 100g $ + $ min @ 1 $ / min $ + $ min @ 1 $ /。使用我们的校正方法的NIR测量在可接受的范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号